THE BROADEST CUTTING AND WELDING RANGE READY FIND OUT MORE close
Home » GAS MANIFOLD MM90 - HP UNIT SEMIAUTOMATIC

GAS MANIFOLD MM90 - HP UNIT SEMIAUTOMATIC

Group Number: 3611

Whole medical range is available on

The MM90 HP unit medical manifold is intended for use in hospital pipeline system as medical gas source. Together with MM90, always use an alarm providing all alarms according to standard (like gas alarm). As 2nd stage is recommended to use a stabilizer. The manifold will deliver gas from the operating bank to the manifold pressure regulator until the cylinders are exhausted. At that point the supply will switch to the reserve bank and the exhausted bank can be replenished. The object gives uninterrupted gas supply.

Gas Alarm is a standard accessory. The gas alarm gives visual and audible indication. It surveils and the alarm sounds when the following happens:

1.  Change operation side
2.  Leakage on reserve side
3.  High operation pressure
4.  Low operation pressure

The Gas alarm is able to communicate with other equipment through relays. 

MM90 INCLUDES THE FOLLOWING COMPONENTS:

  • MM90 HP unit Manifold
  • Gas alarm
  • Purge valves
  • HP filters

FOR A COMPLETE MM90 HP UNIT MANIFOLD ADD:

  • Collecting pipe set (high pressure valves and non-return valves / high pressure components)
  • Cylinder retaining brackets (included in gas cylinder collecting pipe set)
  • High pressure hoses with safety wire
  • Plug for close collecting pipeline
  • Gas name sign
  • Stabilizer

735100000440 MM90 HP unit semi automatic leaflet EN

TECHNICAL DATA

Gases: O2, Air, N2, N2O, CO2, (all medical gases)
Nominal flow: 90 m3/h
Inlet nominal pressure: 200 bar (20 000kPa)
Outlet nominal pressure: 9 bar (setting range 9-15 bar)
Inlet connection: W21,8×1/14"M
Outlet connection: G3/4"F + soldering piece pipe ∅ 22 mm
Intermediate pressure relieve valve: 16 bar
Pressure relieve valve pipe dimension: ∅ 10 mm
Purge valves connection: W21,8×1/14"M + soldering piece pipe ∅ 10 mm

Regulatory status:

 

 

Complies with Medical Devices Directive 93/42/EEC

Complies with EN ISO 7396-1
(Central Gas Supply Systems)

Complies with EN 60601-1-2
(Electromagnetic compatibility)

present SIS HB 370 and HTM 02-01

 

Item No. Denomination  Gas PRV Alarm
0732314 MM90 – HP unit 2×1 O2 Standard Alarm TMA6703
0732315 MM90 – HP unit 2×1 Air Standard Alarm TMA6703
0732316 MM90 – HP unit 2×1 N2O, CO2 Standard Alarm TMA6703
0732320 MM90 – HP unit 2×1 O2, Air With pull-ring Alarm TMA9705
0732321 MM90 – HP unit 2×1 N2O, CO2 With pull-ring Alarm TMA9705
0727327* MM90 – HP unit 2×1 O2, Air, N2, N2O, CO2 Standard

* basic version without electric sensors

Technical Datasheets Top